Running in the photoconductor drum
Running in the photoconductor drum
Attention:
The photoconductor drum can only be run in when printing operation has
stopped.
To run in the photoconductor drum after replacement
[219]
Proceed as follows:
1.
If the printing system has not yet stopped, click the 'Stop' button.
2.
Select the 'VarioStream' 'Changing consumables' 'Run in photoconductor
drum' menu on the operator panel.
3.
Click the 'OK' button to start the procedure.
Information on the icons displayed on the operator panel under 'Work-steps':
see
The photoconductor drum is run in after a preparation period.
4.
Click the 'OK' button on the operator panel to complete the procedure:
All aggregates of the printing system are inspected (duration around
two-three minutes), before the printing system is switched to the 'Ready' sta-
tus.
406
Chapter 9 Replacing expendables
Explanation of icons on page
118.