Synchronization - Barcode Synchronization Mark For Unperforated Paper - Oce VarioStream 8000 User Manual

Continuous printing system
Hide thumbs Also See for VarioStream 8000:
Table of Contents

Advertisement

Synchronization - Barcode synchronization mark for unperforated paper

[91]
Paper without guide holes
Paper with guide holes
Horizontal position of synchronization mark A2 in printing system 2:
The horizontal position of synchronization mark A2 in printing system 2 is set
in sub-menu <Paper> <Sheets> <Mark type> = <Synchronization mark> <Mark
position>.
The limit values depend upon the value set in the sub-menu <Paper> <Paper
width>.
[92]
[92] Minimum and maximum values
Paper without guide
holes
Paper with guide
holes
Vertical position of the synchronization mark (B1, B2):
The vertical position of the synchronization mark can be different in both printing
systems.
The vertical position can be entered for each printing system in the sub-menu
<Paper> <Sheets> <Mark type> = <Synchronization mark> <Mark position>.
The value corresponds to the value for the PTL mark.
[93]
[93] Minimum and maximum values
Minimum value
B1
0
B2
0
Width of synchronization mark (C1, C2):
The width of the synchronization mark is always 10 mm.
The width cannot be changed.
Height of synchronization mark (D1, D2):
The height of the synchronization mark is always 48 mm.
The height cannot be changed.
Upper protected area (E1, E2)
Value for A1
Paper width - 10 mm
Paper width - 10 mm - 12.7 mm
Minimum value for
A2
0 mm
12.7 mm
Maximum value for A2
Paper width - 10 mm
Paper width - 10 mm - 12.7 mm
Maximum value
Page length - 50.8 mm
Page length - 50.8 mm
169

Advertisement

Table of Contents
loading