Oce VarioStream 8000 User Manual page 167

Continuous printing system
Hide thumbs Also See for VarioStream 8000:
Table of Contents

Advertisement

Setting barcode synchronization marks in twin mode "simplex"
[87]
Position barcode synchronization mark
Printer 2
[205]
Horizontal position of synchronization mark (A1, A2):
The horizontal position of the synchronization mark is the same in both printing
systems (A1 = A2).
If this value is changed in the printing system menu, the corresponding value will
be automatically changed in the other menus of both printing systems.
This value can be entered in the sub-menu <Paper> <Sheets> <Mark type> =
<Synchronization mark> <Mark position>. The limit values depend upon the
value set in the sub-menu <Paper> <Paper width>.
[88]
[88] Horizontal minimum and maximum values
Paper without guide
holes
Paper with guide
holes
Vertical position of the synchronization mark (B1, B2):
The vertical position of the synchronization mark must be different in both
printing systems.
When this value is changed in the menu of a printing system, a check is
performed to see if the marks overlap. If they overlap, a note is displayed on the
operator panel.
The vertical position value can be entered in the sub-menu <Paper> <Sheets>
<Mark type> = <Synchronization mark> <Mark position>. The value must
correspond to the PTL mark.
The limit values depend upon the value set in the sub-menu <Paper> <Page
length>.
Synchronization - Barcode synchronization mark for unperforated paper
Minimum value for
A1, A2
0 mm
12.7 mm
Printer 1
[206]
Maximum value for A1, A2
Paper width - 10 mm
Paper width - 10 mm - 12.7 mm