Installing the heating element and completing replacement of the fuser roller
Proceed as follows:
6.
Place the faulty heating element in the empty packaging, close and make
ready for collection by Service.
7.
Close the right door at the back of the printing system.
[562]
8.
[563]
9.
Reconnect the connector plug
to the heating element on the
front of the printing system.
Lay the cable so that the cover
on the handle does not rub
against the cable during the
subsequent swiveling off of the
temperature sensor strip.
Move the temperature sensor
lever to the right. The tempera-
ture sensor strip is swiveled on
again.