Proceed as follows:
[503]
Caution
When removing the discharge corotron cartridge, the nipple on the corotron
wire may fall into the developer station without you noticing. If printing
then continues, the developer station can be irreparably damaged.
When changing the faulty discharge corotron cartridge, always check if the
nipple is still on the corotron wire. If the nipple is missing, search for and
find it.
3.
Check whether the nipple is still on the corotron wire. If the nipple is miss-
ing, search for it. To do this, pull out the developer station (see
developer station. on page
tire area around it. If no nipple is found, remove the photoconductor drum
(see
Removing the photoconductor drum on page
4.
Install discharge corotrons on page
Remove torn discharge corotron
273) and search the developer station and the en-
367.
Clean the
400) and search this area.