Operation Of 16-Bit Timer - Fujitsu MB95630H Series Hardware Manual

8-bit microcontroller new 8fx
Hide thumbs Also See for MB95630H Series:
Table of Contents

Advertisement

MB95630H Series
21.5.7

Operation of 16-bit Timer

The 16-bit timer has a buffer and compare clear function, which is used for
motor speed checking and abnormal detection timeout. The 16-bit timer starts
counting up from counter value "0x0000" after a reset has been completed and
counting enable bit is set.
■ 16-bit Timer Operation
The counter value is cleared in the following conditions:
• When an overflow has occurred.
• When a match with the 16-bit MPG compare clear register (upper/lower) (CPCUR/CPCLR)
is detected.
• When "1" is written to the TCLR bit in the TCSR register during operation.
• When a write timing signal is generated and MODE bit in TCSR is "0".
• When a position detection signal is generated and MODE bit in TCSR is "1".
• Reset
An interrupt can be generated when the counter is cleared due to a match with the compare
clear register. There is no interrupt when an overflow occurs.
Note:
To access the compare clear register and the timer buffer register, the word access
instruction must be used.