state-refresh-interval (PIM view)

Syntax
state-refresh-interval interval
undo state-refresh-interval
View
PIM view
Default level
2: System level
Parameters
interval: State refresh interval in seconds, with an effective range of 1 to 255.
Description
Use state-refresh-interval to configure the interval between state refresh messages.
Use undo state-refresh-interval to restore the default.
By default, the state refresh interval is 60 seconds.
Related commands: pim state-refresh-capable, state-refresh-rate-limit, and state-refresh-ttl.
Examples
# Set the state refresh interval to 70 seconds.
<Sysname> system-view
[Sysname] pim
[Sysname-pim] state-refresh-interval 70

state-refresh-rate-limit (PIM view)

Syntax
state-refresh-rate-limit interval
undo state-refresh-rate-limit
View
PIM view
Default level
2: System level
Parameters
interval: Time to wait before receiving a new refresh message, in seconds and with an effective range of
1 to 65535.
Description
Use state-refresh-rate-limit to configure the time that the router must wait before receiving a new state
refresh message.
Use undo state-refresh-rate-limit to restore the default.
By default, the device waits 30 seconds before it receives a new state refresh message.