Host-Tracking (Mld View); Last-Listener-Query-Interval (Mld View) - HP 6125G Command Reference Manual

Ip multicast
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

host-tracking (MLD view)

Syntax
host-tracking
undo host-tracking
View
MLD view
Default level
2: System level
Parameters
None
Description
Use host-tracking to enable the MLD host tracking function globally.
Use undo host-tracking to disable the MLD host tracking function globally.
By default, this function is disabled.
Related command: mld host-tracking.
Examples
# Enable the MLD host tracking function globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] host-tracking

last-listener-query-interval (MLD view)

Syntax
last-listener-query-interval interval
undo last-listener-query-interval
View
MLD view
Default level
2: System level
Parameters
interval: Specifies an MLD last listener query interval in seconds, namely, the length of time that the
device waits between sending MLD multicast-address-specific queries. The value ranges from 1 to 5.
Description
Use last-listener-query-interval to configure the MLD last listener query interval globally.
Use undo last-listener-query-interval to restore the default.
By default, the MLD last listener query interval is 1 second.
Related commands: display mld interface, mld last-listener-query-interval, and robust-count.