Use undo timer query to restore the default.
By default, the IGMP general query interval is 60 seconds.
Related commands: display igmp interface, igmp timer query, and timer other-querier-present.
Examples
# Set the IGMP general query interval to 125 seconds globally.
<Sysname> system-view
[Sysname] igmp
[Sysname-igmp] timer query 125

version (IGMP view)

Syntax
version version-number
undo version
View
IGMP view
Default level
2: System level
Parameters
version-number: IGMP version, in the range of 1 to 3.
Description
Use version to configure the IGMP version globally.
Use undo version to restore the default.
The default IGMP version is version 2.
Related commands: igmp version.
Examples
# Set the global IGMP version to IGMPv1.
<Sysname> system-view
[Sysname] igmp
[Sysname-igmp] version 1