Version (Mld View) - HP 6125G Command Reference Manual

Ip multicast
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Parameters
interval: Specifies an MLD query interval, namely, amount of time in seconds between MLD general
queries, in the range of 1 to 18,000.
Description
Use timer query to configure the MLD query interval globally.
Use undo timer query to restore the default.
By default, the MLD query interval is 125 seconds.
Related commands: display mld interface, mld timer query, and timer other-querier-present.
Examples
# Set the MLD query interval to 200 seconds globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] timer query 200

version (MLD view)

Syntax
version version-number
undo version
View
MLD view
Default level
2: System level
Parameters
version-number: Specifies an MLD version number, 1 or 2.
Description
Use version to configure the MLD version globally.
Use undo version to restore the default.
By default, the MLD version is MLDv1.
Related commands: mld version.
Examples
# Set the MLD version to MLDv2 globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] version 2