Table 29 Command output
Field
Total 0 (*, G) entry; 1 (S, G) entry
(172.168.0.2, 227.0.0.1)
RP
Protocol
Flag
Uptime
Upstream interface
Upstream neighbor
RPF prime neighbor
Downstream interface(s)
information

display pim rp-info

Syntax
display pim rp-info [ group-address ] [ | { begin | exclude | include } regular-expression ]
Description
Number of (S,G) and (*, G) entries in the PIM routing table.
(S, G) entry in the PIM routing table.
IP address of the RP.
PIM mode.
Flag of the (S, G) or (*, G) entry in the PIM routing table:
2MSDP—The entry is contained in the next SA message to notify an
MSDP peer.
ACT—The entry has been used for routing data.
DEL—The entry will be removed.
EXPRUNE—Some outgoing interfaces are pruned by other multicast
routing protocols.
EXT—The entry contains outgoing interfaces provided by other
multicast routing protocols.
LOC—The entry is on a router directly connected to the same subnet
with the multicast source.
MSDP—The entry is learnt from MSDP SA messages.
NIIF—The entry contains unknown incoming interfaces.
NONBR—The entry has a PIM neighbor searching failure.
RPT—The entry is on a RPT branch where (S, G) prunes have been
sent to the RP.
SPT—The entry is on the SPT.
SWT—The entry is in the process of RPT-to-SPT switchover.
WC—The entry is a wildcard routing entry.
Length of time for which the (S, G) or (*, G) entry has existed.
Upstream (incoming) interface of the (S, G) or (*, G) entry.
Upstream neighbor of the (S, G) or (*, G) entry.
RPF neighbor of the (S, G) or (*, G) entry:
For a (*, G) entry, if this router is the RP, the RPF neighbor of this (*, G)
entry is NULL.
For an (S, G) entry, if this router directly connects to the multicast
source, the RPF neighbor of this (S, G) entry is NULL.
Information of the downstream interfaces, including the following:
Number of downstream interfaces.
Downstream interface name.
Protocol type on the downstream interfaces.
Uptime of the downstream interfaces.
Expiry time of the downstream interfaces.