SmartWare Software Configuration Guide
dial out
authentication pap
identification outbound <user> password <password>
bind interface ppp_interface router
port ethernet 0 0
encapsulation pppoe
no shutdown
pppoe
session green
bind subscriber joe_example
no shutdown

PPP over serial link

Without authentication, numbered interface

context ip router
interface ppp_interface
ipaddress 172.17.1.1 255.255.255.252
point-to-point
port serial 0 0
encapsulation ppp
bind interface ppp_interface
no shutdown

With authentication, unnumbered interface

context ip router
interface ppp_interface
ipaddress unnumbered
point-to-point
subscriber ppp joe_example
dial in
authentication pap
identification inbound <user> password <password>
bind interface ppp_interface router
port serial 0 0
encapsulation ppp
bind interface ppp_interface
no shutdown
Sample configurations