SmartWare Software Configuration Guide
SN(cfg)#port ethernet 0 0
SN(prt-eth)[0/0]#shutdown
Checking the state of the Ethernet port on slot 0 and port 0 shows that the interface was closed.
SN(prt-eth)[0/1]#show port ethernet 0 1
Ethernet Configuration
-------------------------------------
Port
: ethernet 0 0 1
State
: CLOSED
MAC Address
: 00:30:2B:00:1D:D4
Speed
: 10Mbps
Duplex
: Half
Encapsulation
: ip
Binding
: wan@router
Frame Format
: standard
Default Service: 0
Moreover the IP interface, which is bound to the Ethernet port on slot 0 and port 0 gets also closed. Checking
the state of the IP interface wan indicates this with the CLOSED for parameter state.
SN(prt-eth)[0/1]#show ip interface
------------------------------------------------------------
Context:
Name:
IP Address:
MTU:
ICMP router-discovery:
ICMP redirect:
State:
Binding:
Ethernet port configuration task list
router
wan
172.17.100.210 255.255.255.0
1500
enabled
send only
CLOSED
ethernet 0 0 1/ethernet/ip