14 • Serial port configuration
ment size to 300 (Bytes) introduces an additional delay of at most 4.7ms (300 * 8 / 512k) but does not
cause to much fragmentation overhead on large data packets.
SN(frm-rel)[0/0]#pvc 1
SN(pvc)[1]#encapsulation rfc1490
SN(pvc)[1]#fragment 300
SN(pvc)[1]#bind interface external router
SN(pvc)[1]#pvc 2
SN(pvc)[2]#encapsulation rfc1490
SN(pvc)[2]#bind interface internal router
7. Finally we check that the Frame Relay settings are correct.
SN(frm-rel)[0/0]#show framerelay
Framerelay Configuration:
Port
LMI-Type
----------------------------------------------------------
serial 0 0 0
ansi
PVC Configuration:
Port
DLCI
--------------------------------------------------------------
serial 0 0 0
1
serial 0 0 0
2
176
Keepalive
20
State
Fragment
close
disabled
close
disabled
SmartWare Software Configuration Guide
Fragmentation
300
Encaps
Binding
rfc1490
external@router
rfc1490
internal@router