SmartWare Software Configuration Guide
Shutdown and enable POTS ports
Prior to changing any configuration settings on a POTS port, the port must be shut down. You can perform all
configuration tasks and then activate the port, so activating all your configuration changes.
This procedure describes how to disable and activate an POTS port.
Mode: Context CS
Step
Command
1
(config)#port pstn slot port
2
(prt-pstn)[ slot/port ]#down
3
4
(prt-pstn) [ slot/port ]#up
Example: Shutting down and enabling a POTS port.
The following example shows how to enter the configuration mode for POTS port 0/0, disable and activate the port.
172.16.40.71>enable
172.16.40.71#configure
172.16.40.71(cfg)#port pstn 1 0
172.16.40.71(prt-pstn)[1/0]#down
Add here the configuration changes:
172.16.40.71(prt-pstn)[1/0]#up
Shutdown and enable POTS ports
Available codecs for IC-4ab—Only G.711 and G.723 or
G.729 are supported on the IC-4ab, that is it is not possible to
use G.723 on one port of the IC-4ab and G.729 at the same
time on another port.
Enter POTS port configuration mode
Shutdown the port. All active calls are dropped!
Configure settings according to the sections below
Activate the port.
At the end of the configuration procedure re-enabling the port acti-
vates the configuration changes.
28 • POTS port configuration
Purpose
355