31 • VoIP debugging
SmartNode 1: See debug monitor output and show call sessions
14:13:30
CALL
[080007]
CONNECT (Generic Q.931)
14:13:30
CALL
[08000F]
CONNECT ACKNOWLEDGEMENT (Generic Q.931)
14:13:30
CALL
SN1#
SN1#show call sessions 5
[0021]
SN1#
SmartNode 2: Show call sessions
SN2#show call sessions 5
[8000]
SN2#
SmartNode 1: Drop call and see debug monitor output
SN1#call 21 drop
SN1#14:14:49
CALL
[080045]
DISCONNECT (Generic Q.931)
[0803038090]
Cause : normal call clearing
transit network - CCITT - Q.931
14:14:49
CALL
[08004D]
RELEASE (Generic Q.931)
[0803038090]
Cause : normal call clearing
transit network - CCITT - Q.931
14:14:49
CALL
SN1#
SmartNode 2: See debug monitor output
SN2#14:14:50
CALL
[080045]
DISCONNECT (Generic Q.931)
[0803038090]
Cause : normal call clearing
transit network - CCITT - Q.931
14:14:50
CALL
400
> [0021] GOT
> [0021] SENT
> [0021] CONNECTED
> [0021] SENT
> [0021] SENT
> [0021] DROPPED
> [8000] GOT
> [8000] SENT
SmartWare Software Configuration Guide