Panther II 820/1032/2064-205
SIMULTANEOUS/SERIAL
RINGING:
Serial ringing is used
for stand-alone systems to ensure that one ringing line will be heard at a
time. Simultaneous ringing is typically used behind PBX/Centrex (all
ringing signals will be heard simultaneously).
Preprogrammed Value = Serial.
CAMP-ON DURATION: Defines the length of time that a call will
be camped-on before ringing is returned either to the originator or to the
sub-attendant (depending on how Transfer Ringing Return is
programmed for the system). Camp-on duration can be programmed
for 30 seconds, 1 minute, 2 minutes, 3 minutes or 5 minutes.
Preprogrammed Value = 1 minute.
CAMP-ON TONE INTERVAL:
Programmed in conjunction with
"Camp-On Duration", this parameter specifies the time interval that will
elapse between each l-second camp-on tone that is sent to the camped-
on caller. Programmable parameters are 10 seconds, 20 seconds or 30
seconds.
Preprogrammed Value = 20 seconds.
SYSTEM CLEAR: There are three different System Clear
capabilities that are performed on a systemwide basis:
l
The capability of clearing ALL System features and resetting the
system to its preprogrammed values (Access Code 070, Data Code 0),
l
The capability of clearing ALL Common Speed Call numbers for the
system (Access Code 070, Data Code l), or
l
The capability of clearing ALL Private Speed Call numbers from all
Sets (Access Code 070, Data Code 2).
Refer to Table 2-l (a) to perform a SYSTEM CLEAR.