Programming
There are four parameters that you must program for external call forwarding:
l
incoming lines for external call forwarding,
l
the outgoing lines for external call forwarding,
l
the release time, and
l
the external numbers that you want the calls forwarded to.
To program the system for external call forwarding:
Step 1.
Step 2.
Step 3.
step 4.
Step 5.
Step 6.
At
Station JO, dial *# (or press the
Program
key).
Dial 015.
-.
Program
the incoming ECF lines:
a.
Dial access code 0310=Xx where XX=the number of the desired line.
b.
Dial # to store the line number.
,If you programmed a second outgoing ECF line, you must program a second incoming
ECF line,
z:
Dial access code 031 I=XX where XX=the number of the desired line.
Dial # to store the
line number.
Note: To disable incoming
ECF line 1 enter access code 03 IO=00 in step a.
To
disable incom-
ing ECF line 2, enter access code 03 1 l=OO in step c.
Program the outgoing ECF lines that you want assigned to the incoming ECF
lines:
a.
Dial access code 0410=Xx where XX=the number of the desired line for outgoing ECF
line 1.
b. Dial # to store the line number.
If a second outgoing ECF line is desired,
c.
Dial access code 04 1 l=XX where XX=the number of the desired line for outgoing ECF
line 2.
d. Dial # to store the line number.
Note: To disable outgoing ECF line 1 enter access code 04 lO=OO in step a. To disable outgoing
ECF line 2, enter access code 04 1 l=OO
in step c.
Enter the desired DISA/ECF release time. The release time deter-t-nines the
length of time allowed for an ECF call. Note that the length of time selected
will also determine the release time for the Direct Inward System Access fea-
ture. To change the default setting of the release time:
i:
Dial access code 027.
Dial data code 0 for 30 seconds
1 for 1 minute (default setting),
2 for 2 minutes,
3 for 3 minutes,
4 for 5 minutes, or
5 for 10 minutes.
c.
Dial # to store the release time.
Press * to exit programming.