Brocade Communications Systems StoreFabric SN6500B Command Reference Manual page 594

Brocade fabric os command reference v7.1.0 (53-1002746-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

2
nsShow
Partial
LSAN
The following information is displayed only if the device has registered the information (for example, the
switch automatically registers SCSI inquiry data for FCP target devices):
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following optional operands:
-r
-t
566
Displays "Yes" if the device entry is incomplete; otherwise displays "No". Devices
that are incomplete are displayed by the nsShow and nsCamShow commands,
and have routing established, but are not considered during device discovery (for
example, during FC-GS Name Server Queries).
Displays "Yes" if the device is currently part of an active LSAN zone; otherwise
displays "No".
FC4s supported
IP address
Port and node symbolic names
Fabric Port Name. This is the WWN of the port on the switch to which the device is physically
connected.
Port address or port IP address
Replaces the time-to-live (TTL) attribute output with state change registration
(SCR) information. This value indicates what type of RSCN a device registers to
receive. Values include the following:
SCR=0x00000000
Reserved.
SCR=0x00000001
Fabric detected registration. Register to receive all RSCN requests issued by the
fabric controller for events detected by the fabric.
SCR=0x00000002
NX_Port detected registration. Register to receive all RSCN requests issued for
events detected by the affected NX_Port.
SCR=0x00000003
Register to receive all RSCN requests issued. The RSCN request returns all
effected N_Port_ID pages.
The following SCR values use the 4th byte of the SCR value and can coexist with
the SCR values of 0x00000000, 0x00000001, 0x00000002, and 0x00000003.
SCR=0x01000000
Principal switch RSCN registration. Register to receive proprietary RSCN
(principal switch change).
SCR=0x02000000
AG_QOS RSCN registration.
Displays the device type. The device type is defined in terms of two attributes. The
first attribute indicates the origination of the device as one of the following:
Physical
The device is connected to the NX_Port, using FLOGI to log in to the switch.
Fabric OS Command Reference
53-1002746-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents