2
portShow
Protocol
portPhys
portScn
port generation number
portId
portIfId
portWwn
792
Online
Up and running.
Offline
Not online, see portPhys for more detail.
Testing
Running diagnostics.
Faulty
Failed diagnostics.
Persistently Disabled
Persistently disabled.
Protocol used by the port: FC or FCoE.
The port's physical state:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
No_Light
Module is not receiving light (Condor 2 ports only).
No_SigDet
No signal detected; displays when a quad small form-factor pluggables (QSFPs)
is installed without cables).
Mod_Inv
Incompatible vendor or module speed mismatch.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.
The port's last State Change Notification.
The port's generation number for the last offline state change.
The port's 24-bit port ID.
The user port's interface ID.
The port's world wide name.