Brocade Communications Systems StoreFabric SN6500B Command Reference Manual page 946

Brocade fabric os command reference v7.1.0 (53-1002746-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

2
secPolicyCreate
EXAMPLES
To create an FCS policy (While creating the FCS policy, the local switch WWN is automatically included
in the list. Switches included in the FCS list are FCS switches and the remaining switches in the fabric
are non-FCS switches. Out of the FCS list, the switch that is in the first position becomes the Primary
FCS switch and the remaining switches become backup FCS switches. If the first switch in the FCS list is
not reachable, the next switch becomes the Primary):
To create a device policy to allow two devices to attach to domain 3 ports 1 and 3 (the WWN of first
device is 11:22:33:44:55:66:77:aa and the WWN of second device is 11:22:33:44:55:66:77:bb):
To create a SCC policy in a fabric with three switches:
1.
2.
3.
4.
To create a security policy:
918
primaryfcs:admin> secpolicycreate "FCS_POLICY", "3; 4"
FCS_POLICY has been created.
primaryfcs:admin> secpolicycreate "DCC_POLICY_aB_7", \
"11:22:33:44:55:66:77:aa;11:22:33:44:55:66:77:bb;3[1,3]"
DCC_POLICY_abc has been created.
Check if a policy exists.
switch:admin> secpolicyshow
____________________________________________________
ACTIVE POLICY SET
____________________________________________________
DEFINED POLICY SET
Identify switches in the fabric.
switch:admin> fabricshow
Switch ID
Worldwide Name
--------------------------------------------------------------
2:fffc02 10:00:00:05:1e:39:5f:67 10.32.69.53 10.20.30.53 "sw1"
4:fffc04 10:00:00:05:1e:04:ef:0e 10.32.69.49 10.20.30.49 'sw2"
200: fffcc8 10:00:00:05:1e:35:cd:ef 10.32.69.117 10.20.30.117 \
Create a SCC policy that includes switches with domain IDs 2 and 4.
switch:admin> secpolicycreate "SCC_POLICY","2;4"
SCC_POLICY has been created.
Activate the policy.
switch:admin> secpolicyactivate
About to overwrite the current Active
ARE YOU SURE
(yes, y, no, n): [no] y
secpolicyactivate command was completed successfully.
To create an SCC policy that includes all switches in the fabric:
switch:admin> secpolicycreate "SCC_POLICY",*
SCC_POLICY has been created.
switch:admin> secpolicycreate SCC_POLICY,\
"10:00:00:05:1e:a1:ef:b9; 10:00:00:05:1e:a3:00:59; \
10:00:00:05:1e:a2:f9:09" -legacy
SCC_POLICY created as user specified.
switch:admin> secpolicyshow
_______________________________________
ACTIVE POLICY SET
Enet IP Addr FC IP Addr Name
fec0:60:69bc:60:260:69ff:fe80:d4a
fec0:60:69bc:54:205:1eff:fe04:ef0e
"nSW4100_98"
Policy Set.
Fabric OS Command Reference
53-1002746-01

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents