Portledtest - Brocade Communications Systems StoreFabric SN6500B Command Reference Manual

Brocade fabric os command reference v7.1.0 (53-1002746-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

portLedTest

Cycles user port LEDs.
SYNOPSIS
portledtest
[--slot slot_number]
[-ports itemlist]
[-npass count]
[-action value]
ceeportledtest
[--slot slot_number]
[-ports itemlist]
[-npass count]
[-action value]
DESCRIPTION
Use this command to exercise the user port LEDs in the current switch. When used without a slot or port
specifier, all ports are tested.
For each port, the command cycles through the ON and OFF state by setting the ATTN LEDs to green for
the ON condition and unlighted for the OFF condition. The SPEED LEDs are initially set to black before
the test starts. The SPEED LEDs turn green while the test is running.
portLedTest and ceePortLedTest are platform-specific versions of the same test. Use ceePortLedTest
on FCoE platforms only. Use fcipLedTest for GbE port testing on the Brocade 7800 and FX8-24. On all
other platforms, use portLedTest.
This diagnostic cannot be run on an operational switch. You must disable the switch using the
chassisDisable command before you can run this test. After the command completes, the ATTN LEDs
flash amber, indicating that the command has finished and exited. Enable the switch using the
chassisEnable command to set the ATTN LEDs back to black.
NOTES
On 10 Gbps or 16 Gbps (Condor3-based) platforms, you cannot interrupt the test by pressing the return
key (<cr>).
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
--slot slot
-ports itemlist
-npass count
Fabric OS Command Reference
53-1002746-01
Specifies the slot number on bladed systems. When used without the port option,
this option exercises all user ports in the specified slot. When used with the port
option, only the ports specified for the specified slot are tested.
Specifies a list of front-end blade ports to test. When a specific port is specified,
the blade port reference is used. If you want to test a specific user port, you will
need root access to the bladePortMap command to map the specified blade port
to the desired user port. Refer to itemList for more information on the itemlist
parameter. When specifying a ports on a chassis, the -ports operand must be
preceded by the --slot operand. Refer to the example section for an illustration.