2
portCfgShow
To display the QoS configuration for an EX_Port (QoS over FCR deployment):
To display an FCIP Tunnel on a Brocade FX8-24 with and without IPSec information (In the following
examples, IPSec is in legacy mode):
716
switch:admin> switchshow | grep EX-Port
16
16
id
N4
10:00:00:05:1e:41:4a:45 "Tom_100"
(fabric id = 25 )(Trunk master)
switch:admin> portcfgshow 16
Area Number:
Octet Speed Combo:
Speed Level:
Fill Word(On Active)
Fill Word(Current)
AL_PA Offset 13:
Trunk Port
Long Distance
VC Link Init
Desired Distance
Reserved Buffers
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable
LOS TOV enable
NPIV capability
QOS E_Port
Port Auto Disable:
Rate Limit
EX Port
Mirror Port
Credit Recovery
F_Port Buffers
NPIV PP Limit:
CSCTL mode:
Fault Delay
D-Port mode:
D-Port over DWDM:
FEC
switch:admin> portcfgshow fciptunnel 1/12 -ipsec
-------------------------------------------
Tunnel ID: 1/12
Tunnel Description:
Compression: Off
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Enabled (legacy)
IPSec Key: '12345678901234567890123456789012'
QoS Percentages: High 50%, Med 30%, Low 20%
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:52:fe:00
Flags: 0x00000000
FICON: Off
Online
FC
EX-Port \
11
1(16G|8G|4G|2G)
AUTO(HW)
0(Idle-Idle)
0(Idle-Idle)
OFF
ON
LS
OFF
10 Km
86
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
AE
OFF
OFF
ON
OFF
ON
OFF
126
OFF
1(1.2sec)
ON
ON
active
Fabric OS Command Reference
53-1002746-01
Need help?