EXAMPLES
To add an F_Port Top Talker to blade 1 port 2 (which should be an F_Port):
To delete the F_Port Top Talker:
To add the Fabric Mode Top Talker:
To delete the Fabric Mode Top Talker:
To display the Fabric Mode Top Talker output:
To identify and delete a stale Top Talker for an F_Port (the F_Port belonged to a blade that has been
removed):
To install an ingress and an egress Top Talker monitor on the same ASIC with the -force option (in the
following example, ports 1/33 and 1/34 are on the same ASIC. The attempt to install conflicting monitors
fails unless you use the perfTTmon command with the-force option ):
SEE ALSO
perfAddEEMonitor,
Fabric OS Command Reference
53-1002746-01
Switch:admin> perfttmon --add ingress 1/2
switch:admin> perfttmon --del
Switch:admin> perfttmon --add fabricmode
Switch:admin> perfttmon --del fabricmode
Switch:admin> perfttmon --show dom 1 pid
=========================================================
Src_PID
Dst_PID
=========================================================
0x03f600
0x011300
0x03f600
0x011300
Switch:admin> configshow -a | grep perf
perf.ToptalkerEnabledonC2:1
perf.ttmonc.254:254|0|0|1:
Switch:admin> perfttmon --delete -sconfig
switch:admin> perfttmon --add ingress 1/33
switch:admin> perfttmon --add egress 1/34
Cannot install EE/TopTalker Egress monitor because TopTalker
Ingress monitor is already present on one of the ports of this asic
switch:admin> perfttmon --add egress 1/34 -force
perfResourceShow
1/2
MB/sec
Potential E-Ports
121.748
2/0,2/2,2/3
121.748
3/14,3/15
2
perfTTmon
617