To display bottleneck configuration details for the switch:
Backend port credit recovery examples
To enable backend port credit recovery with the link reset only option and to display the configuration:
Fabric OS Command Reference
53-1002746-01
Jan 13 18:54:10
Jan 13 18:54:15
Jan 13 18:54:20
Jan 13 18:54:25
Jan 13 18:54:30
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold
Severity threshold
Switch-wide alerting parameters:
=================================
Alerts
Congestion threshold for alert - 0.800
Averaging time for alert
Quiet time for alert
Per-port overrides for sub-second latency bottleneck criterion:
===============================================================
Slot
Port
TimeThresh
=========================================
1
3
0.500
1
4
0.600
1
5
0.700
Per-port overrides for alert parameters:
========================================
Slot Port Alerts? LatencyThresh CongestionThresh Time(s) QTime(s)
=================================================================
1
1
Y
0.100
1
2
C
--
1
3
L
0.100
1
4
N
--
Excluded ports:
===============
Slot
Port
============
1
2
1
3
1
4
switch:admin> bottleneckmon --cfgcredittools \
-intport -recover onLrOnly
switch:admin> bottleneckmon --showcredittools
Internal port credit recovery is Enabled with LrOnly
Jan 13 18:54:15
Jan 13 18:54:20
Jan 13 18:54:25
Jan 13 18:54:30
Jan 13 18:54:35
- 0.800
- 50.000
- Congestion only
- 300 seconds
- 300 seconds
SevThresh
100.000
50.000
20.000
0.800
0.800
--
--
bottleneckMon
20.00
80.00
0.00
0.00
40.00
300
300
600
600
300
300
--
--
2