Hasyncstop - Brocade Communications Systems StoreFabric SN6500B Command Reference Manual

Brocade fabric os command reference v7.1.0 (53-1002746-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

haSyncStop

Disables High Availability state synchronization.
SYNOPSIS
hasyncstop
DESCRIPTION
Use this command to temporarily disable High Availability (HA) synchronization.
After issuing haSyncStop, the switch does not go back to sync start unless you perform one of the
following actions: reboot the active CP, reboot the standby CP, insert a new standby CP (blade), or issue
the haSyncStart command The time it takes for the HA sync to complete depends on the system
configuration. The HA sync timeout is set to 10 minutes.
NOTES
Disabling HA synchronization may cause failover to be disruptive.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To disable the HA state synchronizing process:
SEE ALSO
haFailover, haShow,
Fabric OS Command Reference
53-1002746-01
switch:admin> hasyncstop
haSyncStart
2
haSyncStop
439