portCfgGport

Designates a port as a G_Port; removes G_Port designation.
SYNOPSIS
portcfggport [slot/]port,mode
DESCRIPTION
Use this command to designate a port as a G_Port. After successful execution of this command, the
switch attempts to initialize the specified port as an F_Port only, and does not attempt loop initialization
(FL_Port) on the port. A port designated as a G_Port can become an E_Port. This configuration can be
cleared but not set on VE/VEX_Ports. Changes made by this command are persistent across switch
reboots or power cycles.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
slot
port
mode
EXAMPLES
To configure port as a locked G_Port:
SEE ALSO
configure, portCfgLport, portShow,
Fabric OS Command Reference
53-1002746-01
For bladed systems only, specify the slot number of the port to be configured,
followed by a slash (/).
Specify the port to be configured, relative to its slot for bladed systems. Use
switchShow to display a list of valid ports.
Specify a value of 1 to designate the port as a G_Port or specify a value of 0 to
remove the G_Port designation from the port. A value of 0 is the default port state.
Mode must be preceded by a comma. This operand is required.
switch:admin> portcfggport 1/3, 1
switchShow
2
portCfgGport
683

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents