Comtech EF Data CDM-570L Installation And Operation Manual page 254

Satellite modem
Hide thumbs Also See for CDM-570L:
Table of Contents

Advertisement

CDM-570/570L Satellite Modem with Optional IP Module
Serial Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Number of
N/A
3 bytes
Unread stored
Events
Retrieve next 5
N/A
75 bytes
unread Stored
Events
Clear All
CAE=
None
Stored Events
Description of Arguments
to Query
Query only.
Unit returns the Number of stored Events, which remain Unread, in
the form xxx.
Note: This means unread over the remote control.
Example: NUE=126
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=ODU
5= Power on/off, or log cleared
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
Command only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments.
Response to
Command
N/A
N/A
CAE=
CAE?
CAE*
CAE#
13–20
Revision 4
MN/CDM570L.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
NUE?
NUE=xxx
(see description of
arguments)
RNE?
RNE={CR}ABCddmmy
yhhmmss{CR}ABCddm
myyhhmmss{CR}ABCd
dmmyyhhmmss{CR}AB
Cddmmyyhhmmss
{CR}ABCddmmyyhhm
mss
(see description for
details of arguments)
N/A
N/A