Managing Hardware Setup

Testing the CTS 1100 Camera

The camera is set up successfully when the image is centered and in focus on the display screen, and the
white balance is configured. The hardware setup software provides a camera Auto Adjust feature and
uses targets to adjust the camera zoom and fine-tune the camera focus.
To set up the CTS 1100 camera for testing, complete the tasks in the following sections:
Removing the Camera Cover and Leveling the Camera
The camera cluster must be perfectly level for you to properly configure the camera. To level the camera,
complete the following steps.
Step 1
Turn the four black plastic screws on the top and bottom of the camera assembly 1/4 turn, then remove
the camera cover, as shown in
Figure 6-2
Place the small
Step 2
camera cluster until the camera assembly is level, as shown in
Cisco TelePresence System Release 1.5 Administrator Guide
6-6
Removing the Camera Cover and Leveling the Camera
Attaching the Large Camera Target to the Easel
Positioning the Table and Starting the Calibration Procedure
Managing Focus Adjustments and Adjusting the Camera Zoom, page 6-9
Focusing the Camera
Saving Your Settings
Attaching the Camera Lens and Hood
Removing the Camera Cover
Cover
release
screws
Cover
release
screws
spirit level
on top of the camera assembly and adjust the leveling screws behind the
Figure
6-2.
Chapter 6
Troubleshooting the CTS 1100
Figure
6-3.
OL-13676-04