Managing Hardware Setup
Positioning the Table and Starting the Calibration Procedure
To correctly position the table and configure the Cisco TelePresence software for use with the CTS 1300
cameras, follow these steps:
Position the table so that there is a minimum of 44 inches between the display and the front of the table,
Step 1
and make sure that the sides of the table are evenly positioned on each side of the CTS 1300.
Make sure that the farthest edge of the table is no farther than 110 inches away from the lower bezel of
Step 2
the display.
The table must be 28 to 32 inches high. 30 inches is the optimal height.
Note
Figure 7-29
44 inches
minimum
Step 3
Make sure that the camera assembly is level by completing the steps in the
and Leveling the Cameras" section on page
Step 4
Build the easel, and attach the large camera target to the easel, by completing the steps in the
the Large Camera Target to the Easel" section on page
32 inches above the ground.
Log in to the Cisco TelePresence System Administration window.
Step 5
Step 6
Select the table type by completing the following steps:
a.
Choose Troubleshooting > Hardware Setup.
b.
Click the Configuration radio button. The table configuration menu appears, as shown in
Figure
c.
Click the Start button to start testing.
d.
Select Short Racetrack Table from the drop-down menu.
Cisco TelePresence System Release 1.6 Administration Guide
7-34
Figure 7-29
shows recommended table positioning.
Short Racetrack Table Positioning
A
B
10 feet
6 feet minimum,
12 feet maximum,
8 feet recommended
30 inches
7-30.
A=B
7-8.
7-11, making sure that the bottom of the target is
Chapter 7
Troubleshooting the CTS 1300
"Removing the Camera Cover