Managing Hardware Setup
Figure 7-38
Tighten the thumbscrews for the zoom and focus rings.
Step 7
Click Hide Camera Targets to remove the alignment images.
Step 8
Click the Setup button, then click the Auto Adjust button.
Step 9
The auto adjust procedure completes. This procedure takes several seconds.
Note
If there is insufficient light, the auto adjust procedure terminates. In this case, add more light to the room
and repeat the auto adjust procedure.
Click Done to complete the procedure.
Step 10
Calibrating the Left Camera
To adjust the zoom and focus the left camera, follow these steps.
Note
If you logged out of the GUI, you must re-select the correct table type after you log in; otherwise, you
could configure your system for the incorrect table type. To select the correct table type, complete
in the
The directions left and right refer to the assembly as you face the display.
Note
Step 1
Move the large camera target to the far left corner of the table, as shown in
Cisco TelePresence System Release 1.6 Administration Guide
7-42
Adjusting the Camera Zoom
"Positioning the Table and Starting the Calibration Procedure" section on page
Chapter 7
Troubleshooting the CTS 1300
7-51.
Figure
7-39.
OL-13676-04
Step 5