Part Code 7105 - HP StorageWorks P9000 Manual

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 61 Error codes (part code 7010) (continued)
Part
Error
Code
Number
7010
59069
7010
66102
7010
66560
7010
69025

Part code 7105

Table 62 Error codes (part code 7105)
Part
Error
Code
Number
7105
5099
7105
5625
7105
5626
7105
6502
7105
6503
7105
6520
7105
7310
7105
8500
7105
8501
252 Message (part code group 7nnn)
Error Message
The P-VOL and the S-VOL belong to
different SLPRs. If you perform this
operation, the storage partition
administrator will become unable to
operate.
Do you want to continue this operation?
Information was updated by other users.
The list will scroll to the top.
The maximum number of Pairs or
Volumes that can be displayed in the
Preview List is 16,384. Change the
number of pairs or volumes that is
displayed in the Preview List to 16,384
or less.
Some pairs are excluded from the pairs
to be set, because pairs in invalid status
for Pairsplit operation or Snapshot pair
is included in the specified pairs.
Error Message
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
An internal logic error occurred.
The specified volume cannot be used
because it is write-protected by Volume
Retention.
Processing in progress. Please wait for
a while, and then retry the operation.
The volume status is being changed to
simplex.
The command has been rejected,
because the specified volume was
registered in the Security Group that
cannot specify T-VOL or reserved volume.
This error code is not registered.
Sufficient amount of shared memory is
not installed or the program product is
not installed.
The command has been rejected,
because the command specified last time
is being processed.
Recommended Action
Please contact HP Technical Support.
Click [OK], then continue the operation.
Change the number of pairs or volumes
displayed in Preview to 16,384 or less.
Change the status of the excluded pair.
Pairsplit operation cannot be executed
from Remote Web Console, if the
specified pair is a Snapshot pair.
Recommended Action
If this problem persists, please contact
HP Technical Support.
Please contact HP Technical Support.
Release the write-protection by Volume
Retention.
Wait a while, and retry the operation.
Wait a while, and retry the operation.
Execute one of the following:
Change the attribute of the Security
Group so that the Security Group can
specify T-VOL or reserved volume.
Remove the volume specified from the
Security Group.
If this problem persists, please contact
HP Technical Support.
Add shared memory or confirm whether
the necessary program product key is
installed.
Wait a while, and retry the operation.
Severity
Level
E
W
W
W
Severity
Level
E
W
W
W
W
W
E
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents