Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8772
Change pair operation failed due to
communication error or the R-VOL status
is invalid.
6005
8773
Pair change was refused because
M-VOL is suspended.
6005
8775
Multi platform feature already installed
in RCU.
6005
8776
A volume cannot be used as an M-VOL
when:
it is used by Continuous Access
Journal or Continuous Access Journal
Z.
it is used by Business Copy Z or
Compatible FlashCopy.
6005
8777
Combination of MCU with RCU
controller type is not supported.
6005
8778
One side of the Cache or shared
memory on the RCU is blocked.
6005
8779
Continuous Access Synchronous or
External Storage Access Manager is
not supported under the RCU controller
type.
6005
8780
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8781
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8785
The M-VOL is defined as the expansion
volume.
6005
8786
The R-VOL is defined as the expansion
volume.
Recommended Action
The pair option change
operation failed, either
because a communication
error occurred or because
the R-VOL status is not valid.
Verify the status, and view
the License Key window at
the RCU side to check the
licensed capacity for
Mainframe Array
Management. If the licensed
capacity for Mainframe
Array Management is
insufficient, purchase a
license key for a larger
capacity.
Resume the pair for the
M-VOL, then retry the
operation.
The multiplatform feature has
already been installed in the
RCU. Verify the
configuration of the RCU.
Select another volume.
Check the controller type of
the specified MCU and
RCU, then contact HP
Technical Support.
There is an invalid cache or
shared memory status on the
RCU. Check the status and
recover the cache or shared
memory, then retry the
operation.
Confirm the controller type
of the RCU.
Install the Continuous Access
Synchronous Z in the MCU
and the RCU.
Install the Continuous Access
Synchronous Z in the MCU
and the RCU.
Check the volume again.
Check the volume again.
Severity Level
W
W
W
W
W
E
W
W
W
W
W
Part code 6005