Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58687
6505
58688
6505
58689
6505
58690
6505
58691
6505
58692
6505
58693
6505
58694
6505
58695
6505
58696
202 Message (part code group 6nnn)
Error Message
The status of the other mirror of the Delta
resync did not change.
Delta resync failed because the specified
primary data volume was not ready for
Delta resync.
The operation failed, because the status
of some mirrors in the master or restore
journal was invalid. Check the status of
the mirrors in the specified journal.
The recovery to the status ready for Delta
resync failed, because the status of the
specified primary data volume was one
of the following:
The primary data volume is being
copied; correction copy or drive copy
is in progress.
The primary data volume is in
correction access status.
The primary data volume is blocked
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
The specified mirror ID is already used
in the restore journal.
Specify another mirror ID.
The specified master journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
The specified restore journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
The Delta resync operation failed. Check
the status of the secondary data volume,
or the status of the connected
communication line.
No more journals can be allocated to
the specified command device.
Delete the journals registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
The specified volume cannot be used as
a journal volume because the volume is
an external volume to which the I/O
suppression mode is enabled.
Recommended Action
If the problem persists despite retrying,
contact HP Technical Support.
Check the status of the specified primary
data volume.
Check the status of the mirrors in the
specified journal.
Check the status on the primary data
volume.
Specify another mirror ID.
Check the status of the master journal.
Check the status of the restore journal.
Check the status of the secondary data
volume, or the status of the connected
communication line. When no
abnormality is found in the status of the
secondary data volume or the
communication line, please contact HP
Technical Support.
Delete the journal registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
Check the I/O suppression mode of the
specified volume.
Severity
Level
W
W
W
W
W
W
W
W
W
W