Table 59 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
58582
7005
58583
7005
58584
7005
58585
7005
58630
7005
58631
7005
58632
7005
5871 1
7005
68000
7005
68001
7005
68021
7005
68737
246 Message (part code group 7nnn)
Error Message
The command has been rejected,
because the specified S-VOL is used as
P-VOL of Snapshot or the specified MU
number is already used.
The operation failed because the volume
was shared by a Snapshot pair.
The operation failed because the volume
was shared by a Snapshot pair in COPY
(RS-R) status.
The operation failed because the CU
group of the specified volume is not
supported.
The operation failed because the
specified P-VOL was used by Delta
resync of Continuous Access Journal.
The operation failed because the
specified S-VOL was used by Delta
resync of Continuous Access Journal.
The reserve volume setting failed
because the specified volume was used
by Delta resync of Continuous Access
Journal.
The operation failed because the
specified MU number was already used.
Specify other MU numbers.
A pair cannot be created because the
volume specified as P-VOL is not a Thin
Provisioning volume (V-VOL) but the one
specified as S-VOL is.
Quick Restore cannot be executed
because the pair contains Thin
Provisioning volume (V-VOL).
"0" cannot be specified as the MU
number of L2 pair.
Specify other MU numbers.
The command has been rejected,
because the specified P-VOL is a Thin
Provisioning volume not associated with
a pool.
Recommended Action
The specified command cannot be
executed with the current pair
composition.
See the section about the interoperability
with other products and functions and
the Business Copy described in the HP
StorageWorks P9000 Snapshot User
Guide for the condition of sharing the
volumes between Snapshot and Business
Copy.
To continue the operation, release the
Snapshot setting.
Check the conditions for using Business
Copy in conjunction with Snapshot.
Volumes that do not belong to CU group
0 are currently not supported. Specify
another volume.
The command cannot be executed in the
current status of Continuous Access
Journal pair.
See the section about sharing Business
Copy volumes in the HP StorageWorks
P9000 Business Copy User Guide for
the relationship between the state of the
Continuous Access Synchronous pair and
the Business Copy operations.
The P-VOL of Continuous Access Journal
pair for Delta resync cannot be specified
as S-VOL. Specify another volume.
The P-VOL of Continuous Access Journal
pair for Delta resync cannot be specified
as a reserved volume.
Specify another volume.
Refresh the Business Copy window, and
check the MU number that can be used.
When you specify the volume to S-VOL,
specify V-VOL to P-VOL as well.
Use Reverse Resync.
Specify other MU numbers.
Associate the Thin Provisioning volume
with a pool, then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W