Table 59 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
8517
The number of S-VOL cylinders exceeds
the maximum.
7005
8518
You cannot create a pair because the
track format is different.
Make sure that the specified emulation
type is the same for both.
7005
8519
Volumes specified as P-VOL and S-VOL,
or those constituting LUSE are not
consistent in capacity.
7005
8520
You cannot set a pair, because the
volume type is different for each.
7005
8521
The number of multiple copy jobs
exceeded the maximum.
7005
8522
The emulation type of the P-VOL is not
supported.
7005
8523
The emulation type of the S-VOL is not
supported.
7005
8524
The emulation type is not supported.
7005
8525
An internal logic error occurred.
7005
8526
An internal logic error occurred.
7005
8527
An internal logic error occurred.
7005
8528
An internal logic error occurred.
7005
8529
An internal logic error occurred.
7005
8530
An internal logic error occurred.
7005
8531
An internal logic error occurred.
7005
8532
The command has been rejected,
because the P-VOL or the S-VOL is being
used by the host.
7005
8533
The command has been rejected,
because the emulation type of the
specified volume is not supported or the
specified S-VOL is used as a data volume
of Continuous Access Journal.
7005
8535
A processor failure was detected.
7005
8536
A cache failure was detected.
Recommended Action
Check the contents, and retry.
Check if the specified emulation type is
the same or not.
Select volumes with the same capacity.
When specifying LUSE volumes as P-VOL
and S-VOL, the capacity of each volume
constituting the LUSE volumes must be
the same.
Specify the volume of the same emulation
type, and retry the operation.
Check the contents, and retry.
Specify the emulation type supported in
HOMRCF.
Specify the emulation type supported in
HOMRCF.
Specify the emulation type supported in
HOMRCF.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Stop the usage by the host.
Specify a volume of the supported
emulation type. When the S-VOL is used
as a data volume of Continuous Access
Journal, the command cannot be
executed in the current status of
Continuous Access Journal pair.
See the section "Sharing Business Copy
volumes" in the HP StorageWorks P9000
Business Copy User Guide for the
relation between the status of Continuous
Access Journal pair and the Business
Copy operations.
Please contact HP Technical Support.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
W
W
E
E
E
E
E
E
E
W
W
E
E