HP StorageWorks P9000 Manual page 45

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 21 Error codes (part code 0605) (continued)
Part
Error
Error Message
Code
Number
0605
58332
The external volume is blocked.
0605
58406
The configuration of Continuous Access
Journal or Continuous Access Journal Z
is defined.
0605
58407
The reserved volume setting for
Continuous Access Journal or Continuous
Access Journal Z is defined.
0605
58409
The cache mode cannot be changed
when the Disconnect External Storage
Systems or the Disconnect External
Volume is in progress.
0605
58410
The cache mode cannot be changed
because the bind mode is set to the
specified volume.
0605
5841 1
Set the same cache mode to all the
volumes that compose a LUSE volume.
0605
58622
The configuration of Pool VOL is defined.
0605
58623
The specified operation cannot be done,
because the Snapshot pair using the Pool
VOLs to be maintained is in PSUS status
or being restored.
0605
58626
A Snapshot pair is defined.
0605
58710
The specified volumes include remote
command devices registered in the
extended consistency group of
Continuous Access Journal Z.
0605
58905
The extended shared memory for
External Storage is not installed.
0605
65740
The configuration changing processes
are conflicting at DKC.
0605
65791
The specified External Path Group is not
mounted.
0605
65792
The specified External Path Group has
already been mounted.
0605
65793
The specified External Path Group has
already been used.
0605
65794
The specified external volume is not
mounted.
0605
65795
The specified external volume has
already been specified.
Recommended Action
Ensure that the external volume is not
blocked, then retry the operation.
Release the configuration definition of
Continuous Access Journal or Continuous
Access Journal Z, then retry the
operation.
Release the journal volume setting for
Continuous Access Journal or Continuous
Access Journal Z, then retry the
operation.
Execute the Reconnect External Storage
Systems or the Reconnect External
Volumes, put the external volume in
normal status, then retry the operation.
Release the bind mode setting, then retry
the operation.
If there is a volume whose cache mode
cannot be changed due to its bind mode
setting, release the bind mode setting
first.
Release the configuration definition of
Pool VOL, then retry the operation.
Resynchronize or release the definition
of Snapshot pair, then retry the
operation.
Cancel the pair definition, then retry the
operation.
Delete all the Journal registered in the
extended consistency group, then retry
the operation.
The extended shared memory for
External Storage needs to be installed.
Please contact HP Technical Support.
Check if the configuration changing
process by RAID Manager, Auto LUN,
or Quick Restore is not in the operation,
then retry the operation.
Check the specified External Path Group.
Check the specified External Path Group.
Clear the duplicated setting, then retry
the operation.
Check the specified external volume.
Exclude the duplicated setting, then retry
the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 0605
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents