Table 21 Error codes (part code 0605) (continued)
Part
Error
Code
Number
0605
8102
0605
8122
0605
8136
0605
8140
0605
8958
0605
8966
0605
8979
0605
56513
0605
56515
0605
56516
0605
56517
0605
56519
0605
56520
0605
58258
0605
58263
0605
58330
0605
58331
44
Message (part code group 0nnn)
Error Message
This function is not supported.
Another maintenance processing is in
progress.
The command was rejected, because the
licensed capacity has exceeded the
maximum.
The configuration of Compatible
FlashCopy is defined.
An error occurred on the DKC side.
An error occurred on the DKC side.
The operation of the external volume has
been failed because all the paths to the
external volume are blocked.
An emulation type that cannot be added
is specified.
The Disconnect External Storage Systems
or the Disconnect External Volumes is not
executed for the target volume.
The configuration of Continuous Access
Synchronous or Continuous Access
Synchronous Z is defined.
The configuration of Business Copy,
Business Copy Z, or Snapshot is defined.
The reserved volume setting for Business
Copy or Business Copy Z is defined.
The reserved volume setting for Auto LUN
is defined.
All the paths to the external volume are
blocked.
No paths will be available, if you
change the setting of paths.
After executing the Disconnect External
Storage Systems or the Disconnect
External Volumes, neither the Reconnect
External Paths nor the Disconnect
External Paths can be executed.
The specified External Path is not
registered.
Recommended Action
Check whether the DKCMAIN microcode
version and the SVP microcode version
are mismatched.
Wait for a while, then retry the
operation.
Check the licensed capacity, then specify
it within the licensed capacity or add the
licensed capacity.
Release the configuration definition of
Compatible FlashCopy, then retry the
operation.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Restore more than one path to the
external volume, then perform the
operation of the external volume.
Check the emulation type. If you want to
change the cache segment size to set the
specified emulation type, please contact
HP Technical Support.
Execute the Disconnect External Storage
Systems or the Disconnect External
Volumes, then retry the operation.
Release the configuration definition of
Continuous Access Synchronous or
Continuous Access Synchronous Z, then
retry the operation.
Release the configuration definition of
Business Copy, Business Copy Z, or
Snapshot, then retry the operation.
Release the reserved volume setting for
Business Copy or Business Copy Z, then
retry the operation.
Release the reserved volume setting for
Auto LUN, then retry the operation.
Restore the blocked path status, then
retry the operation.
Make the setting of the paths to keep at
least one path available, then retry the
operation.
Execute the Reconnect External Storage
Systems or the Reconnect External
Volumes, then retry the operation.
Check the specified External Path.
Severity
Level
W
W
W
W
E
E
W
W
W
W
W
W
W
W
W
W
W

Advertisement