HP StorageWorks P9000 Manual page 277

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 65 Error codes (part code 8105) (continued)
Part
Error
Error Message
Code
Number
8105
1918
An external volume is mapped to the
external port to be operated.
8105
1926
The path cannot be set to the specified
volume, because the volume is being
used as a quorum disk.
8105
1927
The specified volume cannot be set as a
command device, because it is being
used as a quorum disk.
8105
2003
An error occurred during SVP
processing.
8105
2005
An error occurred during SVP
processing.
8105
2009
An error occurred during SVP
processing.
8105
2010
The LDEV is being used by the host, or
an error occurred in the SVP procedure.
8105
201 1
The status of the storage system requires
maintenance (for example, the storage
system is blocked, the shared memory is
inconsistent, or some other factor).
8105
2013
An error occurred during SVP
processing.
8105
2015
An error occurred while connecting to
the storage system.
8105
2082
Processing is disabled because the host
is mounted or the device is reserved.
8105
2083
The subsystem status is invalid.
8105
2084
The subsystem status is invalid.
8105
2097
The host specified by the WWN is
performing I/O operations.
8105
2204
Devices to be maintained include journal
volumes.
8105
2205
Devices to be maintained include journal
volumes.
8105
2504
No settings can be made because of a
volume reserved for RAID Manager.
Recommended Action
Delete the external volume that is
mapped to the external port to be
operated, then retry the operation.
Check the setting.
Check the setting.
Use the SVP to check if the DKC is in the
normal status, then retry. If the same
problem persists despite retrying, please
contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Recovery processing may take about 1
minute. Wait for a while.
Please contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If the same error occurs despite retrying,
please contact HP Technical Support.
Unmount the host and cancel reservation
of the device. If the host is an AIX host,
unmount the host, and execute the
varyoffvg command.
Check the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
Check the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
Check the settings, then retry the
operation.
Delete or suspend all pairs to which the
journal volumes belong.
Delete all pairs to which the journal
volumes belong.
Release the reserved attribute of the
target volume by using Data Retention.
Severity
Level
W
W
W
E
E
E
W
E
E
W
E
W
W
W
W
W
W
Part code 8105 277