HP StorageWorks P9000 Manual page 47

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 21 Error codes (part code 0605) (continued)
Part
Error
Error Message
Code
Number
0605
66509
The total LDEV capacity defined in the
external volume exceeds the external
volume size.
0605
66510
The specified emulation type cannot be
used.
0605
66512
Specified CLPR is not mounted.
0605
66517
The target external volume has already
been mapped or set for mapping.
0605
66518
The External Path configuration of the
target external volume is not
corresponding to that of another external
volume in the same External Path Group.
0605
66520
Mainframe volume and intermediate
volume cannot be set because the
package for mainframe system is not
mounted.
0605
66568
Multiple operation tags are defined.
0605
66675
The syntax of the parameter is invalid.
0605
66692
The volume in the local storage system
cannot be operated.
0605
66693
A correct parameter as a data transfer
volume is not set.
0605
66694
A correct parameter as
RemoteCommandDevice is not set.
0605
66695
Specified port is not external port.
0605
66697
The value entered as PathMode is
outside the setting range.
0605
66698
The number of alternate Path definitions
that can be set to the external volume
has exceeded the maximum.
0605
66699
The number of LDEV definitions that can
be set to the external volume has
exceeded the maximum.
0605
66702
The value of External Path Group is not
set within the available range.
0605
66705
It is not Port number that can be
specified.
0605
66710
It is not set within the range where LUN
can be used.
0605
66713
The value of ExG is not set within the
available range.
0605
66715
Attribute is invalid.
0605
66718
It is not set within the range where CLPR
can be used.
0605
66720
It is not emulation type that can be
specified.
Recommended Action
Check the setting of LDEV capacity.
Check the setting of emulation type.
Check the setting of CLPR.
Check the configuration and the setting
of external volume.
Check the setting of path configuration.
Check the mounted packages.
Check the contents of the spreadsheet.
Check the syntax of parameter.
Specify the volume in an external storage
system.
Check the setting of target external
volume.
Check the setting of target external
volume.
Specify the external port.
Check the value entered as PathMode.
Check the number of alternate Path
definitions.
Check the number of LDEV definitions.
Check the setting of External Path Group.
Check the setting of Port number.
Check the setting of LUN.
Check the setting of ExG.
Check the setting of Attribute.
Check the setting of CLPR.
Check the setting of emulation type.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 0605
47