Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58563
6505
58564
6505
58565
6505
58566
6505
58590
6505
58591
6505
58592
6505
58593
6505
58594
6505
58595
198 Message (part code group 6nnn)
Error Message
The specified volume cannot be
registered because the volume has failed
to recover from blockade. Please retry
the operation.
If this problem persists, please contact
HP Technical Support and request to
format the volume.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was being shredded by
Data Retention. Retry the operation after
the shredding is completed.
The Add Pair (Paircreate) operation
failed because the specified secondary
data volume was being shredded by
Data Retention. Retry the operation after
the shredding is completed.
The specified volume cannot be
registered as a journal volume because
the volume is being shredded by Data
Retention.
Retry the operation after the shredding
is completed.
The operation of Add Pair (Paircreate)
or the Resume Pair (Pairresync) failed,
because the journal volumes of the
specified master journal were blocked.
The operation of Add Pair (Paircreate)
or the Resume Pair (Pairresync) failed,
because the journal volumes of the
specified restore journal were blocked.
The specified operation failed because
the subsystem was being powered on or
powered off.
The storage system has accepted the
request normally, however the processing
requires some time. If this message is
displayed after a setting operation,
please refresh the window and check
whether the setting is reflected. If the
setting is not reflected despite refreshing
the window, please retry the operation.
The Paircreate operation failed because
the configuration of the LUSE volume was
different between the primary data
volume and the secondary data volume.
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary subsystem does not
support LUSE volumes.
Recommended Action
Retry the operation.
If this problem persists, please contact
HP Technical Support and request to
format the volume.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Check the journal volumes statuses of the
specified master journal.
Check the journal volumes statuses of the
specified restore journal.
Check the status of the storage system.
Retry the operation after the storage
system has started.
Wait for a while, and refresh the
window. If this message is displayed
after a setting operation, check whether
the setting is reflected. When the setting
is not reflected, retry the operation.
Check the LUSE volume configuration of
the primary data volume and the
secondary data volume.
Confirm that the Continuous Access
Journal function of the secondary storage
system supports LUSE volumes.
Severity
Level
W
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500