Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
8100
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
6505
8102
This function is not supported.
6505
8700
Please retry operation.
6505
8701
The logical path between the local and
the remote subsystems is invalid.
6505
8702
The status of the primary data volume is
not valid.
6505
8703
The specified number of paths is less
than the minimum number of paths in the
DKC Option window.
6505
8704
The specified number of paths is less
than the minimum number of paths in the
DKC Option window, due to a
communication error between the local
and the remote storage systems.
6505
8705
The path could not be deleted due to a
communication error between the local
and the remote subsystems.
6505
8706
Parameter specified by Remote Copy
operation is invalid.
6505
8708
The pair status of the secondary data
volume is incorrect.
6505
8709
Remote Copy operation was rejected.
6505
8710
The pair status of the specified data
volume is incorrect.
6505
871 1
The specified parameter is incorrect.
6505
8712
The operation was rejected due to a
'FREEZE' state.
6505
8713
The port group already exists on the
specified port.
6505
8714
An internal error occurred.
6505
8715
The number of paths is incorrect.
Recommended Action
Retry the operation. If this problem
persists, please contact HP Technical
Support.
Check whether the DKCMAIN microcode
version and the SVP microcode version
are mismatched.
Retry the operation.
Check the path status and edit the path
again.
Refresh and check the window. If
possible, retry the operation on the
primary data volume.
Check the number of paths.
Check the path status in the DKC Status
window, then restore the paths.
Check the CHA status on the window. If
the CHA is blocked, replace the CHA,
then retry the operation.
Enter the correct data.
Refresh the window, and check the pair
status. If possible, retry the operation on
the secondary data volume.
Replace the channel adapter, then retry
the operation.
Refresh the window, and check the pair
status of the pair. If the pair status can
be manipulated, retry the operation.
Check the port number, ID, and LUN of
the storage system.
If you are performing a path operation,
retry the operation after the FREEZE
status is released.
If you are performing a pair operation,
check the DKC status, wait until the SCP
time elapses, then retry the operation.
Exchange the port type after deleting the
group setting.
Please contact HP Technical Support.
Ensure that the number of paths is
correct, then retry the operation. If the
problem persists, please contact HP
Technical Support.
Severity
Level
E
E
W
W
W
W
W
E
W
W
E
W
W
W
W
E
W
Part code 6505 177