HP StorageWorks P9000 Manual page 81

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 31 Error codes (part code 3005) (continued)
Part
Error
Error Message
Code
Number
3005
6050
An error occurred during SVP
processing.
3005
6533
An error occurred during SVP
processing.
3005
6537
There is an error in another setting and
the setting processing has not been
executed.
3005
7060
An error occurred during SVP
processing.
3005
71 1 1
An error occurred during SVP
processing.
3005
7310
An error occurred during SVP
processing.
3005
8000
An error occurred during SVP
processing.
3005
8001
A communication time-out error
occurred in the disk subsystem.
3005
8002
An error occurred during SVP
processing.
3005
8100
An error occurred while connecting to
the subsystem.
3005
8102
This function is not supported.
3005
8102
This function is not supported.
3005
8979
The operation of the external volume
has been failed because all the paths
to the external volume are blocked.
3005
55505
The specified operation cannot be
performed, because the Pool-VOL in the
same Pool has been specified to
migrate to a different CLPR.
Pool ID=%s
3005
55506
The specified volume is used as a
reserved volume of Auto LUN.
3005
55507
The specified volume is used as a
command device.
3005
55508
The specified volume has Volume
Security for Mainframe setting.
3005
55509
The specified volume is used as a LUSE
volume.
3005
55510
An error occurred during SVP
processing.
Recommended Action
If nothing changes despite retrying,
contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Check the error factor in the others
settings.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Check whether the DKCMAIN
microprogram version and the SVP
microprogram version are mismatched.
Check whether the DKCMAIN
microprogram version and the SVP
microprogram version are mismatched.
Restore more than one path to the
external volume, and then perform the
operation of the external volume.
Check the setting.
Release the reserved volume setting or
specify another volume.
Release the command device setting or
specify another volume.
Release the Volume Security for
Mainframe setting or specify another
volume.
Release the LUSE volume setting or
specify another volume.
If this problem persists, please contact
HP Technical Support.
Severity
Level
E
E
W
E
E
E
E
E
E
E
E
E
W
W
W
W
W
W
E
Part code 3005
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents