HP StorageWorks P9000 Manual page 221

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 55 Error codes (part code 6510) (continued)
Part
Error
Error Message
Code
Number
6510
59325
A pair which is ready for Delta resync
cannot be created under the current
status of the specified master journal.
Check the status of the specified master
journal.
6510
59326
Specify a mirror ID other than "0" if you
create a pair ready for Delta resync.
6510
59327
You cannot specify [Entire] or [None] to
the Initial copy mode under the current
status of the specified master journal.
Check the status of the specified master
journal.
6510
59328
The journal volume cannot be deleted,
because the attribute of mirror for the
journal is "master" and the status of the
mirror is "Hold" or "Holding."
6510
59329
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
6510
59330
The local DKC cannot be specified for
the extended consistency group (EXCTG),
because the serial number other than the
local DKC is entered.
Delete the entered DKC to use the journal
of the local DKC.
6510
59331
A LUSE volume is included in the
specified volumes.
The current version of the microcode
does not allow you to create pairs using
LUSE volumes.
6510
59335
The value of the path watch time is not
entered or is outside the range. Check
the value of the path watch time.
6510
65664
The specified volume is not valid for this
program product. Specify another
volume.
6510
65665
The specified volume is not the volume
to be monitored. Check the monitoring
setting.
6510
65777
The current microcode version of
DKCMAIN cannot assign remote
command devices to mirrors.
6510
65778
No more remote command devices can
be assigned to the specified mirror.
6510
65779
There are no mirrors available to assign
a remote command device.
Recommended Action
Check the status of the specified master
journal.
Specify a mirror ID other than 0.
Check the status of the specified master
journal.
Change the status of mirror of the journal
to "Initial," then retry the operation.
Click the check box when you add the
journal of the local DKC to the extended
consistency group (EXCTG).
Delete the entered DKC to use the journal
of the local DKC.
Check whether the specified volume is
a LUSE volume. Also, check storage
system's microcode version.
Check the value of the path watch time.
Specify another volume.
Check the monitoring setting.
The microcode versions between the
DKCMAIN and the SVP might not match.
Confirm the microcode versions of the
DKCMAIN and the SVP.
Check if a remote command device was
assigned to the specified mirror.
Check if the specified journals include
mirrors available to assign a remote
command device.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6510 221

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents