HP StorageWorks P9000 Manual page 58

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 25 Error codes (part code 1005) (continued)
Part
Error
Code
Number
1005
1 135
1005
1 138
1005
1 140
1005
1 170
1005
1 174
1005
1 177
1005
1 178
1005
1 180
1005
1 181
1005
1 194
1005
1 199
1005
1350
1005
1352
1005
1353
1005
1354
1005
1355
58
Message (part code group 1nnn)
Error Message
When setting the port information (Fibre
Address/Fibre Topology/Channel
Speed), multiple change instructions are
set to the same port.
The same setting is specified at LUNM
operation.
Because the Port Group setting is done,
it is impossible to change.
The volume cannot be configured as a
command device because the volume
does not have Read/Write attribute.
The specified host ID is already
registered.
The specified host is already registered.
An incorrect host name was specified.
An error occurred during SVP
processing.
The specified path cannot be added,
because the volume is used by a Remote
Copy pair.
No information can be changed about
this external port because the port has
an external volume.
The path cannot be set to the specified
volume because the volume is not an
open-systems volume.
You could not add the path to the
initiator or external port.
Logical paths remain on the Fibre-MCU
port. This operation may cause a fatal
damage to the logical paths. Please stop
this operation. If you want to continue
this operation, please remove the logical
paths from the MCU port first.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
You could not register the WWN to the
initiator or external port.
You could not change the host mode of
the host group that you connected to the
initiator or external port.
Recommended Action
Check the setting(s), then retry the
operation.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Release the Port Group setting.
Correct settings, then retry.
Correct the settings, then retry.
Correct the settings, then retry.
Correct the settings, then retry.
If this problem persists, please contact
HP Technical Support.
Correct the specification, then retry the
operation.
Correct the settings, then retry.
Check the setting.
To add a path, change the attribute of
the specified port to Target or RCU
Target.
Since the port you are trying to set is for
Remote Copy, you must delete the logical
path, then retry the port setting.
Since the port you are trying to set is for
Remote Copy, you must delete the S-VOL
logical path that is set to RCU Target,
then retry the port setting.
To register the WWN, change the
attribute of the specified port to Target
or RCU Target.
To change the host mode, change the
attribute of the specified port to Target
or RCU Target.
Severity
Level
W
W
W
W
W
W
W
E
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents