Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
5861 1
6505
58612
6505
58613
6505
58614
6505
58615
6505
58616
6505
58617
6505
58618
6505
58620
6505
58621
6505
58624
6505
58625
6505
58627
200 Message (part code group 6nnn)
Error Message
The specified operation failed because
the microcode exchange was in progress
on the subsystem in the extended
consistency group (EXCTG).
The previously executed update
processing of the extended consistency
group (EXCTG) has not completed.
Please wait for a while, and then retry
the operation.
The command device is specified
incorrectly.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journal is not
registered.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is not
registered in the specified journal.
The specified journal cannot be added
to extended consistency group (EXCTG).
Journals cannot be added to the
extended consistency group (EXCTG),
because the attributes of the EXCTG and
the journal are different.
Journals cannot be added to the
extended consistency group (EXCTG),
because the timer type of the specified
journal is not "System."
The status of the extended consistency
group (EXCTG) is changing. Wait for a
while, refresh the window, and then retry
the operation.
Journals cannot be added to the
extended consistency group (EXCTG),
because the attribute of the specified
journal is invalid.
Journals cannot be added to the
extended consistency group (EXCTG),
because the combination of the serial
number and the command device is
invalid.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journals are being
used by another program product.
The specified operation failed because
the command device was not registered
or has been blocked.
Recommended Action
Retry the operation after the microcode
exchange completes.
Wait a while, then retry the operation.
Check whether the specified CU number
and the LDEV number indicate a
command device.
Check if the specified journal is
registered.
Check the mirror ID of the specified
journal.
Check the state of the journal in the
storage system where the specified
journal belongs to, or the installation
status of the program product.
Check the attributes of the specified
extended consistency group (EXCTG)
and the journal.
Check the timer type of the specified
journal.
Wait a while, refresh the window, then
retry the operation.
Check the attribute of the specified
journal.
Check if the specified command device
exists in the device of specified serial
number.
Check if the specified journal is being
used by other program product you are
using.
Check the status of the command device.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W

Advertisement