Table 29 Error codes (part code 2005) (continued)
Part
Error
Error Message
Code
Number
2005
1925
The combination order of LUSE volume
is incorrect.
2005
2005
An error occurred during SVP
processing.
2005
2009
An error occurred during SVP
processing.
2005
2013
An error occurred during SVP
processing.
2005
2015
An error occurred while connecting to
the storage system.
2005
2032
An error occurred while connecting to
the storage system.
2005
2082
Processing is disabled because the host
is mounted or the device is reserved.
2005
2083
The subsystem status is invalid.
2005
2084
The subsystem status is invalid.
2005
2098
The operation cannot be performed,
because the SVP microcode version does
not match the DKCMAIN (subsystem)
microcode version.
2005
2099
The operation cannot be performed,
because an inoperative Processor exists.
2005
2502
The specified volume cannot be
combined as a LUSE volume because it
is not Read/Write attribute (S-VOL
enabled).
2005
2503
The LUSE volume cannot be released
because the attribute of the specified
volume is not Read/Write (S-VOL
enabled).
2005
3002
An error occurred during SVP
processing.
2005
3003
An error occurred during SVP
processing.
2005
3006
An error occurred during SVP
processing.
2005
5013
An error occurred during SVP
processing.
2005
6012
An error occurred during SVP
processing.
Recommended Action
Check the settings.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If the same error occurs despite retrying,
please contact HP Technical Support.
If the same error occurs despite retrying,
please contact HP Technical Support.
Unmount the host and cancel reservation
of the device. If the host is an AIX host,
unmount the host, and execute the
varyoffvg command.
Check the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
Check the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
If the problem persists, please contact
HP Technical Support.
Wait a while, then retry the operation.
If the same problem persists, please
contact HP Technical Support.
Correct settings, then retry.
Correct settings, then retry.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Severity
Level
W
E
E
W
W
W
W
W
W
E
W
W
W
E
E
E
E
E
Part code 2005