Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58306
6505
58307
6505
58308
6505
58324
6505
58325
6505
58326
6505
58327
6505
58328
6505
58329
6505
58333
6505
58334
6505
58335
192 Message (part code group 6nnn)
Error Message
The specified secondary data volume is
used as a command device.
The specified secondary data volume is
an On-Demand (Just in Time) volume.
The specified primary data volume is
used as a command device.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was a P-VOL of Continuous
Access Synchronous or External Storage
Access Manager or an M-VOL of
Continuous Access Synchronous Z.
The specified primary data volume is
used by Continuous Access Synchronous,
External Storage Access Manager, or
Continuous Access Synchronous Z. The
operation failed because the status of
the Continuous Access Synchronous pair,
the External Storage Access Manager
pair, or the Continuous Access
Synchronous Z pair was inappropriate.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was shared by Continuous
Access Synchronous (or Continuous
Access Synchronous Z) and Business
Copy (or Business Copy Z).
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was an LUSE volume.
The operation of Add Pair (Paircreate)
or Resume Pair (Pairresync) cannot be
performed, because the data are
remained in the journal cache for the
restore journal.
The operation of Add Pair (Paircreate)
or Resume Pair (Pairresync) cannot be
performed, because the data are
remained in the journal cache for the
master journal.
The parameter related to the inflow
cannot be changed, because the
specified journal is a restore journal.
The parameter related to the inflow
cannot be changed, because the status
of the specified journal is neither "Initial"
nor "Stopped."
The timer type cannot be changed,
because the status of the specified
journal is not "Initial."
Recommended Action
Check the configuration of the specified
secondary data volume.
Check the configuration of the specified
secondary data volume.
Check the configuration of the primary
data volume.
Confirm the controller type of the RCU.
Check the status of the specified primary
data volume in the Continuous Access
Synchronous, External Storage Access
Manager, or the Continuous Access
Synchronous Z window.
If the primary data volume is in PSUS,
PSUE or Suspend status, restore the
volume, then retry the operation.
If the primary data volume is in COPY
or Pending status, retry the operation
after the status of the volume changes to
PAIR or Duplex.
Specify another primary data volume,
and retry the operation.
Specify another primary data volume,
and retry the operation.
Please contact HP Technical Support.
Please contact HP Technical Support.
Check the attribute of the specified
journal.
Check the status of the specified journal.
Check the status of the specified journal.
Severity
Level
W
W
W
W
W
W
W
E
E
W
W
W