Table 25 Error codes (part code 1005) (continued)
Part
Error
Error Message
Code
Number
1005
1 108
The following volumes cannot be
specified when you change the
command device configurations:
Volumes reserved by Auto LUN
Volumes other than the open-system
volumes (including unmounted
volumes)
System Disk volume
1005
1 1 10
Invalid characters are specified in the
nickname to be used in HOST GROUP
and WWN.
1005
1 1 1 1
When requesting a configuration change
of LUN-Security, a nickname is not
specified. Specify the nickname of HOST
GROUP.
1005
1 1 16
When registering WWN, the value is
not specified. Or, zero is set as the value
of WWN. Be sure to set the WWN
value before requesting the configuration
change.
1005
1 123
Command device security cannot be set
to the specified volume because the
volume is not a command device.
1005
1 125
There are no host groups where the
WWN will be registered.
1005
1 128
An error occurred. If this problem
persists, please contact HP Technical
Support.
1005
1 130
You cannot specify the default nickname
when setting the nickname of a host
group or a host.
1005
1 131
No more host groups can be set,
because the number of host groups has
reached the maximum (254) that can be
set in a port.
1005
1 132
Failed to set the WWN because the
number of WWNs exceeds the
maximum that can be set in a port.
1005
1 133
Failed to set the host mode because the
number of host modes exceeds the
maximum that can be set in a port.
1005
1 134
Failed to set the path because the
number of paths exceeds the maximum
that can be set in a port.
Recommended Action
Check the setting, then retry the
operation.
Check the setting(s), then retry the
operation.
Check the setting(s), then retry the
operation.
Check the setting(s), then retry the
operation.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Check the setting(s), then retry the
operation.
Correct the specified contents, and
request again.
No more host groups can be set,
because the number of host groups has
reached the maximum (254) that can be
set in a port. Reduce the number of host
groups, then retry the operation.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
Part code 1005