Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58697
The journal volume cannot be deleted
from the specified journal due to the
mirror status.
6505
58698
The operation failed because the
specified secondary data volume was
used by Delta resync.
6505
58699
The operation to change the status to the
status ready for Delta resync failed
because the specified secondary data
volume was used by one of the following
program products.
Business Copy/Snapshot
Business Copy Z
Compatible FlashCopy
6505
58700
The operation to change the status to the
status ready for Delta resync failed.
The specified secondary data volume
should meet the following requirements.
The specified volume is a secondary
data volume of another mirror.
The pair status of the specified volume
is PAIR or Duplex.
6505
58701
The Delta resync operation failed,
because journal data of the master
journal were insufficient.
6505
58702
The Delta resync operation failed,
because the number of pairs for each
mirror of the restore journal was
different.
6505
58703
The Delta resync operation failed
because the secondary data volume was
updated.
6505
58704
The operation to change the status to the
status ready for Delta resync failed
because the status of the volumes was
one of the following:
The P-VOL for Continuous Access
Synchronous or External Storage
Access Manager and the primary
data volume for Continuous Access
Journal are different.
The M-VOL for Continuous Access
Synchronous Z and the primary data
volume for Continuous Access Journal
Z are different.
Recommended Action
Check the mirror status of the specified
journal.
Check the status of the secondary data
volume.
Check the status of the specified
secondary data volume in the Business
Copy/Snapshot window, the Business
Copy Z window, or the Compatible
FlashCopy window.
Check the status of the specified
secondary data volume.
Delta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
Check the number of pairs for each
mirror of the restore journal.
Delta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
Check the status of the data volumes in
the Continuous Access Synchronous,
Continuous Access Synchronous Z,
Continuous Access Journal or the
Continuous Access Journal Z window.
Severity
Level
W
W
W
W
W
W
W
W
Part code 6505 203